APPA

Features

-

Thermocouple Module (11) / AC Current transducer (15) / Pen-type Multimeter (17A)

-

Converts any DMM into a thermometer (11)

-

-50°C to 1000°C / -58°F to 1830°F range (11)

-

AC 300A Capability (15)

-

1.9% basic accuracy (15)

-

4200 count digital resolution (17A)

-

Autorranging and manual selection (17A)

Features

-

Thermocouple Module (11) / AC Current transducer (15) / Pen-type Multimeter (17A)

-

Converts any DMM into a thermometer (11)

-

-50°C to 1000°C / -58°F to 1830°F range (11)

-

AC 300A Capability (15)

-

1.9% basic accuracy (15)

-

4200 count digital resolution (17A)

-

Autorranging and manual selection (17A)

MODEL

11

SPECIFICATIONS

Temperature Scale

Celsius or Fahrenheit user-selecatable

Input

Single K-type thermocouple

Output to Meter

1mVdc per °C or °F

Measurement Range

-50°C ~ 1000°F / -58°F ~ 1830°F

Accuracy

-19°C~350°C, ±(0.5%+2°C),

-3°F~662°F, ±(0.5%+4°F),

351°C~500°C, ±(2.0%+2°C),

663°F~932°F, ±(2.0%+4°F),

501°C~1000°C, ±(2.9%+2°C),

933°F~1832°F, ±(2.9%+4°F),

-50°C~-20°C, ±(2.0%+2°C)

-58°F~-4°F, ±(2.0%+4°F)

GENERAL

Operating Temperature

0°C ~ 50°C, ≤80% RH

Storage Temperature

-20°C~60°C

Temperature Coefficient

0.1 x (Spec. Acc) / °C, <18°C or >28°C

Relative Humidity

0% ~ 80%

Power Requirement

Standard 9V battery, NEDA 1604 JIS 006P IEC 6F22

Battery Life: In hours

(Alkaline battery)

300

Size: W x L x D

46 x 122 x 30mm

Weight

114g

 

MODEL

15

SPECIFICATIONS

Current Range

0.1A to 300A a.c. RMS

Output Voltage

1mV a.c. per 0.1 Amp a.c.

Accuracy

±(1.9%+0.5A), 50Hz to 60Hz

±(3.9%+1A), 40Hz to 400Hz

GENERAL

Operating Temperature

0°C ~ 50°C, ≤80% RH

Storage Temperature

-20°C~60°C

Safety

CAT II 600V

Jaw Opening

Ø30mm max.

Conductor Size

Up to 29mm diameter

Size: W x L x D

72 x 102 x 36mm

Weight

150g

 

MODEL

17A

SPECIFICATIONS

DCV

1mV~600V

ACV

1mV~600V

Resistance

0.1Ω~42MΩ

Diode Test

2.000V

Continuity Test

<50Ω, 2kHz tone buzzer

GENERAL

Temperature Coefficient

0.15 x (Spec. Acc) / °C <18°C or >28°C

Measuring rate

2 times / sec

Operating Temperature

0°C ~ 50°C, ≤80% RH

Storage Temperature

-20°C~60°C

Ralative Humidity

0 ~ 80% (0°C ~ 35°C)

0 ~ 60% (35°C ~ 50°C)

Safety

CAT II 600V

Low Battery Indication

Power Requirements

IEC LR03, UM4 or AAA size 1.5V x 2

Battery Life: In hours

(Alkaline battery)

800

Size: W x L x D

42 x 145 x 24mm

Weight

120g, without probes

Included with instrument

Test Lead, Long Test Probe, Short Test Probe,

Alligator Clip, Zinc Battery, Manual